WEIGL ASCII-Commands for ProCommander Series (ProCommander 2, PHX, ES, LX, LTC), WEMC-1 & Pro I/O S
ASCII
serial
Baud: 9600
Bits: 8
Parity: n
Stop Bits: 1
ethernet
Port: 5555
Type: udp
IP Address: 192.168.000.201
Volume Master Set – New Master Volume level for All (Store in EE-Prom)
Reboot – Reboots designated unit in the same way a power cycle would
RTCC Set Time – Sets real time clock time to HH:MM.SS
RTCC Set Date – Sets real time clock date to Day, Month, Year, name
Volume Master Change – New Master Volume level for All (0-31, 32=EProm)
Volume Master Step – New Master Volume level for All by step
Volume Master Fade – Fade to new Master Volume level; level (0-31, 32=EProm), time (s)
Time Code Create – Creates time code: format, start time (optional)
Scheduler Set Time – Sets schdeuler clock time to HH:MM.SS
Show Start Normal – Normal mode: a showstart is only possible if no show is running
Show Start Add – If the new show is not running, it will be started to running shows: max 5
Show Start Terminate – All shows with a different number are terminated and the show is started.
Show Start Interrupt – All shows are stopped, the new show is started
Show Start Restart – The new show will be started of if it is running, it will be restarted.
Show End – The show will be stopped
Show Pause – Pause show number; 0=any show
Show Continue – Continue show number; 0=any show
Show Shuffle – One of the shows between the ranges will be started, or restarted if already running.
Time Code Sync – Sync to time code enable/disable, timeout to internal clock, etc
Show Start Normal Loop – Normal mode: a showstart is only possible if no show is running. Once started show runs in loop.
Show Start Add Loop – If the new show is not running, it will be started to running shows: max 5. Once started, run in loop
Show Start Terminate Loop – All shows with a different number are terminated and the show is started. Once started, run in loop
Show Start Interrupt Loop – All shows are stopped, the new show is started. Once started, run in loop
Show Start Restart Loop – The new show will be started of if it is running, it will be restarted. Once started, run in loop
Send Serial Data – Sends ASCII characters
Play Single Track – Play single track (one folder supported) 8.3 file naming
Playlist Play Loop Track Order – Play all tracks in folder in loop on audio output; Track order as stored in list
Playlist Play Loop Shuffle – Play all tracks in folder in loop on audio output; Track order random
Playlist Stop – Stops immediately current running playlist
Playlist End – Current running track will be finished, then the playlist stops.
Track Pause – Current running track will be paused
Track Continue – Current track will be continued (unpaused)
Track Stop – All current running tracks will be stopped
Polyphonic Activate – Activate/Disable polyphonic mode
Polyphonic Volume – Mute/Adjust volume of polyphonic channel
Display Message – Displays message for X Seconds
Get Variable Content – Get integer variable value into “VariableContent” variable (using !gvcX#)
Watchdog – Network Watchdog – Toggles between 0 and 1 to see if the network is “alive”.
Get Scheduler Time – Run time since last card insertion and is the Reference time for any commands in control.ini
Get Timecode – Return status and time stamp
Set IP Address – Sets the IP Address (new IP Address is stored in the EE-Prom)
Variable Modify to Constant – Variable modify with constant value (Per ProCommander Spec)
Variable Modify to Variable Value – Variable modify with value of other varible (Per ProCommander Spec)
Get Input Status – Gets the current status of the 16 remote input pins.
Get Analog Input – Gets the current analog value of input X.
Get Variables – Get the values of the first 100 variables.
Get Variables – Get the values of the all 250 variables.
Error
Status 255
TCState “Unknown”
TCCurrent 00:00:00.00
Run Time “00:00.00”
Volume Master 17
VariableContent 0
LastWatchdogReceived 0
InputStatus
AnalogInputValue
RawData
VariableValues
GetVariablesRawData